Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem ; 69(10): 1174-1185, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37537871

RESUMO

BACKGROUND: HIV infections often develop drug resistance mutations (DRMs), which can increase the risk of virological failure. However, it has been difficult to determine if minor mutations occur in the same genome or in different virions using Sanger sequencing and short-read sequencing methods. Oxford Nanopore Technologies (ONT) sequencing may improve antiretroviral resistance profiling by allowing for long-read clustering. METHODS: A new ONT sequencing-based method for profiling DRMs in HIV quasispecies was developed and validated. The method used hierarchical clustering of long amplicons that cover regions associated with different types of antiretroviral drugs. A gradient series of an HIV plasmid and 2 plasma samples was prepared to validate the clustering performance. The ONT results were compared to those obtained with Sanger sequencing and Illumina sequencing in 77 HIV-positive plasma samples to evaluate the diagnostic performance. RESULTS: In the validation study, the abundance of detected quasispecies was concordant with the predicted result with the R2 of > 0.99. During the diagnostic evaluation, 59/77 samples were successfully sequenced for DRMs. Among 18 failed samples, 17 were below the limit of detection of 303.9 copies/µL. Based on the receiver operating characteristic analysis, the ONT workflow achieved an F1 score of 0.96 with a cutoff of 0.4 variant allele frequency. Four cases were found to have quasispecies with DRMs, in which 2 harbored quasispecies with more than one class of DRMs. Treatment modifications were recommended for these cases. CONCLUSIONS: Long-read sequencing coupled with hierarchical clustering could differentiate the quasispecies resistance profiles in HIV-infected samples, providing a clearer picture for medical care.


Assuntos
Infecções por HIV , HIV-1 , Humanos , Infecções por HIV/tratamento farmacológico , Quase-Espécies/genética , HIV-1/genética , Antirretrovirais/farmacologia , Antirretrovirais/uso terapêutico , Mutação , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Análise por Conglomerados
2.
J Clin Microbiol ; 60(1): e0176921, 2022 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-34788113

RESUMO

Bacterial pathogens that cannot be identified using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) are occasionally encountered in clinical laboratories. The 16S rRNA gene is often used for sequence-based analysis to identify these bacterial species. Nevertheless, traditional Sanger sequencing is laborious, time-consuming, and low throughput. Here, we compared two commercially available 16S rRNA gene sequencing tests that are based on Illumina and Nanopore sequencing technologies, respectively, in their ability to identify the species of 172 clinical isolates that failed to be identified by MALDI-TOF MS. Sequencing data were analyzed by the respective built-in programs (MiSeq Reporter software of Illumina and Epi2me of Nanopore) and BLAST+ (v2.11.0). Their agreement with Sanger sequencing on species-level identification was determined. Discrepancies were resolved by whole-genome sequencing. The diagnostic accuracy of each workflow was determined using the composite sequencing result as the reference standard. Despite the high base-calling accuracy of Illumina sequencing, we demonstrated that the Nanopore workflow had a higher taxonomic resolution at the species level. Using built-in analysis algorithms, the concordance of Sanger 16S with the Illumina and Nanopore workflows was 33.14% and 87.79%, respectively. The agreement was 65.70% and 83.14%, respectively, when BLAST+ was used for analysis. Compared with the reference standard, the diagnostic accuracy of Nanopore 16S was 96.36%, which was identical to that of Sanger 16S and better than that of Illumina 16S (69.07%). The turnaround time of the Illumina workflow and the Nanopore workflow was 78 h and 8.25 h, respectively. The per-sample cost of the Illumina and Nanopore workflows was US$28.5 and US$17.7, respectively.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala , Genes de RNAr , Humanos , RNA Ribossômico 16S/química , RNA Ribossômico 16S/genética , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Fluxo de Trabalho
3.
J Virol Methods ; 299: 114333, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34656702

RESUMO

The increasing prevalence of N501Y variants of SARS-CoV-2 has kindled global concern due to their enhanced transmissibility. Genome sequencing is the gold standard method to identify the emerging variants of concern. But it is time-consuming and expensive, limiting the widespread deployment of genome surveillance in some countries. Health authorities surge the development of alternative assay to expand screening capacity with reduced time and cost. In this study, we developed an in-house TaqMan minor groove binder (MGB) probe-based one-step RT-qPCR assay to detect the presence of N501Y mutation in SARS-CoV-2. A total of 168 SARS-CoV-2 positive respiratory specimens were collected to determine diagnostic accuracy of the RT-qPCR assay. As a reference standard, PANGO lineages and the mutation patterns of all samples were characterised by whole-genome sequencing. The analytical sensitivity and the ability of the assay to detect low frequency of N501Y variants were also evaluated. A total of 31 PANGO lineages were identified from 168 SARS-CoV-2 positive cases, in which 34 samples belonged to N501Y variants, including B.1.1.7 (n = 20), B.1.351 (n = 12) and P.3 (n = 2). The N501Y RT-qPCR correctly identified all 34 samples as N501Y-positive and the other 134 samples as wildtype. The limit-of-detection of the assay consistently achieved 1.5 copies/µL on four different qPCR platforms. N501Y mutation was successfully detected at an allele frequency as low as 10 % in a sample with mixed SARS-CoV-2 lineage. The N501Y RT-qPCR is simple and inexpensive (US$1.6 per sample). It enables robust high-throughput screening for surveillance of SARS-CoV-2 variants of concern harbouring N501Y mutation.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Reação em Cadeia da Polimerase em Tempo Real , Sequenciamento Completo do Genoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...